Rozwiązania i Komponenty dla AutomatykiSolutions and Components for Automation

Green graphic HMI panels

panele HMI Green

Green Series is a new generation of industrial HMI operator panels.

It is characterized by modern design, excellent work support for the user, which distinguishes it among high-quality HMI panels. The Green series has been used the most popular processor on the market, thanks to which products are characterized by excellent performance and lifetime

The Green series consists of three subtypes:

GH - advanced series, equipped with up to 4 serial ports, Ethernet, standard USB and slave master port, built-in power isolation and serial port isolation

G - standard series, equipped with 3 serial ports, Ethernet, standard USB and slave master port, built-in power isolation

GL - economy series, equipped with 2 serial ports, Ethernet, a standard USB and slave master port

Free software

Seria Green współpracuje z nowym orprogramowaniem konfiguracyjnym Kinco DTools. Dostępne jest w kilku wersjach językowych: angielskiej, rosyjskiej, koreańskiej i chińskiej. Design wspiera wszystkie czcionki zainstalowane w systemie komputerowym.

VNC umożliwia współpracę pomiędzy HMI i HMI, HMI i PC, urządzeniami mobilnymi typu smartfon. Wspiera użyteczne komponenty takie jak przeglądanie PDF, zarządzanie zapisami logów do projektowania interfejsu zarządzajacego. Ma łatwy łatwy i przyjazny w użyciu interfejs.

ProductDisplayResolutionWorking temperatureTouchpadprocessorMemoryportsCommunication interfaceAdditional featuresAsk for a product
GL150E151024 x 768 px-10-55YES32-bit RISC 792 MHz128MB Flash + 128MB DDR3 PORT COM COM0: RS232 / RS485 / RS422 COM: RS232Ethernet-
GL070E.7800 x 480 px0-50 YES32-bit RISC 792MHz32MB Flash + 32MB DDR3, COM0: RS232 / RS485-2 / RS485-4, COM1: RS232 / RS485-2 / RS485-4, COM2: RS232Ethernet-
GL10010.11024 x 600 px0-50 YES32-bit RISC 792 MHz128MB Flash + 128MB DDR3PORT COM COM0: RS232 / RS485 / RS422 COM: RS232-
GH043E4.3” TFT480 x 272-10-55ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR3USB COM0: RS232 / RS485 / RS422; COM2: 232Ethernet1x SD Card
GL0434.3” TFT480 x 272 px0-50°CYes32-bit RISC 792MHz128MB Flash + 128MB DDR3COM0: RS232 / RS485 / RS422; COM2: 232--
GL043E4.3” TFT 480 x 272 px0-50°CYes32-bit RISC 792MHz 128MB Flash + 128MB DDR3COM0: RS232 / RS485 / RS422; COM2: 232Ethernet-
GH0707” TFT800 x 480-10-55ºCYes32-bit RISC 792 MHz128MB Flash + 128MB DDR3USB COM0: RS232 / RS485 / R422; COM1: RS232 / RS485 / R422; COM2: RS-232; COM3: 485-1x SD Card
GL100E10.11024 x 600 px0-50YES32-bit RISC 792 MHz128MBFlash + 128MB DDR3PORT COM COM0: RS232 / RS485 / RS422 COM: RS232Ethernet-
GL104E10.4" TFT800 x 600 px0-50YES32-bit RISC 792 MHz129MB Flash + 128MB DDR3PORT COM COM0: RS232 / RS485 / RS422 COM: RS232Ethernet-
GL070 7800 x 480 px0-50YES32-bit RISC 792MHz128MB Flash + 128MB DDR3Com COM0: RS232 / RS485? Rs422; COM2: 232-
GH070E7” TFT800 x 480 px-10-55°CYes32-bit RISC 792MHz128MB Flash + 128MB DDR3COM0: RS232 / RS485 / RS422; COM1: RS232 / RS485 / RS422; COM2: RS-232; COM3: 485Ethernet1x SD Card
G070E7” TFT800 x 4800-50ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR3USB COM0: RS232 / RS485 / RS422; COM1: RS485; COM2: 232Ethernet-
GH104E10.4”800 x 600 px -10-55°CYes32-bit RISC 792MHz 128MB Flash + 128MB DDR3COM0: RS232 / RS485 / RS422; COM1: RS232 / RS485; COM2: RS232; COM3: 485Ethernet1x SD Card
G070E-CAN7” TFT800 x 4800-50ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR2USB COM0: RS232 / RS485 / RS422; COM1: RS485; COM2: 232Ethernet-
GH0434.3” TFT480 x 272-10-55ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR3USB COM0: RS232 / RS485 / RS422; COM2: 232-1x SD Card
GH150E15” TFT 1024 x 768 px-10-55°CYes32-bit RISC 792MHz128MB Flash + 128MB DDR3COM0: RS232 / RS485 / RS422; COM1: RS232 / RS485 / RS422; COM2: RS232 COM3: 485Ethernet1x SD Card
G0707” TFT800 x 4800-50ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR3USB COM0: RS232 / RS485 / RS422; COM2: 232--
GL070E7” TFT (16:9W)800 x 480 px0-50ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR2COM0: RS232 / RS485 / RS422; COM2: 232EthernetReal time RTC clock
G10010.1" TFT1024 x 600-20 - 60ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR3COM0:RS232/RS485/RS422; COM1:RS485/RS422; COM2:RS232--
G100E10.1” TFT1024 x 600-20 - 60ºCYes32-bit RISC 792MHz128MB Flash + 128MB DDR3COM0:RS232/RS485/RS422; COM1:RS485/RS422; COM2:RS232Ethernet, Modbus-
×

We respect your right to privacy and we protect your personal information. The data you provide in the contact form will allow you to receive the answer to the question (a) in the Message field.

According to art. 13 of the general regulation on the protection of personal data of 27 April 2016 (Journal of Laws UE L 119 of 04.05.2016; hereinafter: RODO) informs you that:

  • The administrator of your Personal Data is P.P.H. WObit E.K.J. Ober s.c., Deborzyce 16, 62-045 Pniewy;
  • with the Data Protection Inspector, you can contact us at the following e-mail address iod@wobit.com.pl ;
  • the provided personal data will be processed on the basis of art. 6 par. 1 lit. f) RODO; these data will be processed to respond to correspondence and direct marketing of own products, which may be related to the question you are asking us;
  • Your personal data will be kept for a period of time compliant with the Civil Code, necessary to claim any claims;
  • You have the right to request the administrator to access your personal data, the right to rectify it, delete it, limit processing, data transfer rights, the right to object;
  • if it is found that the processing of your personal data violates the provisions of the GDPR, you have the right to lodge a complaint with the Inspector General for Personal Data Protection (after 25 May 2018 - the President of the Office for Personal Data Protection);
  • providing personal data is voluntary, although it must be possible to respond to the message sent; failure to indicate personal data may result in the impossibility of sending to us - the message of the way;
  • Your data will not be stored on servers in a third country / outside of the European economic area;
  • Your personal data will not be processed in an automated way in the form of profiling;
  • Your data will not be processed in other marketing activities;